APW Wyott EF-30 Betriebsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
10
CHECK DATA PLATE & CONNECT TO 208 OR 240V AS INDICATED
MODEL #
VOLTS
WATTS
AMPS
WIRE
VOLTS
WATTS
AMPS
WIRE
EF30-iNT
240
11400
23.8 & 23.8
12
208
8560
20.6 & 20.6
12
Wire sizes listed above are for reference only. Check local
Codes or the National Electrical Code for sizes to be used.
CHECK DATA PLATE & CONNECT TO 208 OR 240V AS INDICATED
MODEL #
VOLTS
WATTS
AMPS
WIRE
EF30-iNTC-208
208
11400
55.0
4
Wire sizes listed above are for reference only. Check local
Codes or the National Electrical Code for sizes to be used.
THIS UNIT TO BE CONNECTED TO 1Ø ONLY
THIS UNIT TO BE CONNECTED TO 1Ø ONLY
THIS APPLIANCE HAS MORE THAN ONE POWER
SUPPLY CONNECTION POINT. DISCONNECT ALL
POWER SUPPLIES BEFORE SERVICING
Seitenansicht 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 16 17

Kommentare zu diesen Handbüchern

Keine Kommentare